Mid-Week Connection (Initialization and Binding) with New UUID for Mass Quote Systems

The purpose of this test is to verify that the client system can:

  • recover undelivered business messages from the CME system during the mid-week initialization and binding
  • adjust the inbound and outbound sequence numbers as needed

Pre-Registered and On-Demand Format

Note: This test is used for both Pre-Registered and On-Demand formats. The image below shows the Pre-Registered format version of the test.

 

Note: If a test is not proceeding to the next step, selecting the Refresh button ( ) below the test steps may resolve the issue.

  • To run a Mid-Week Connection (Initialization and Binding) with New UUID for Mass Quote Systems test:
  1. Select a SenderComp from the drop-down and select ASSIGN if a SenderComp is not already assigned.
  2. From the Contracts drop-down, select the desired contract if the contract is not already locked.
  3. Select the START TEST button.

Note: DO NOT select the START TEST button once the test process is in progress.

  1. Over the MSGW connection, submit a two-sided Mass Quote (35=i) message having a quantity greater than 5
  2. Receive and process an Execution Report - New Order message and Terminate the session
  3. On the same segment 99, submit a Negotiate message with a new UUID.
  4. Receive and process a Negotiate Response message.
  5. Submit an Establish message to bind connection.
  6. Select Yes or No to indicate whether your system received and processed the Establishment Acknowledgment message.
  7. Submit a Retransmit Request message for the undelivered Execution Report.
  8. Select Yes or No to indicate whether your system received and processed the Retransmission message for the undelivered Execution Report.
  1. Submit a Sequence message.
  1. Receive and process a Sequence message.