User Help System
Respond to Resend Request
This test verifies that your system can respond to a Resend Request by gap fill.
Additional Drop Copy Information
See the following documentation for more information on Drop Copy functionality:
- Drop Copy Service for iLink - EBS Market
- iLink 3 Binary Order Entry - EBS Market on CME Globex
- iLink FIX Tag Library
- Select a SenderComp from the drop-down and select ASSIGN if a SenderComp is not already assigned.
- Select the START TEST button.
Note: DO NOT select the START TEST button once the test is in progress.
- To run the Respond to Resend Request test:
- Over a Drop Copy connection, submit a Heartbeat (35=0) message.
- Receive and process a Resend Request (35=2) message.
- Submit a Sequence Reset - Gap Fill (35=2, 123-GapFillFlag=Y) message.
- Submit a Heartbeat (35=0) message.
- Receive and process a Heartbeat (35=0) message.
- Submit a Heartbeat (35=0) message.