User Help System
Mid-Week Key Rotation
This test verifies that the client system can properly logon to the CME system using the security enhancement functionality with key rotation. You will need two valid keys to complete this test.
Additional Drop Copy Information
See the following documentation for more information on Drop Copy functionality:
- Drop Copy Service for iLink - EBS Market
- iLink 3 Binary Order Entry - EBS Market on CME Globex
- iLink FIX Tag Library
- Select a SenderComp from the drop-down and select ASSIGN if a SenderComp is not already assigned.
- Select the START TEST button.
Note: DO NOT select the START TEST button once the test is in progress.
- To complete the Mid-Week Key Rotation test:
- Over the Drop Copy connection, submit a Logon (35=A) message using the first secure key pair.
- Receive and process a Logon (35=A) confirmation message.
- Receive and process a Test Request (35=1) message.
- Submit a Heartbeat (35=0) message.
- Submit a Logout (35=5) and process a Logout (35=5) confirmation.
- Over the MSGW connection again, submit a Logon (35=A) message using a different set of secure key pairs other than the ones used in step 3.
- Receive and process a Logon Confirmation (35=A) message.
- Receive and process a Test Request (35=1) message.