User Help System
Manual Order Indicator Tests
The following instructions illustrate the process to run and complete manual order indicator tests.
- To select the test:
- Select a SenderComp from the drop-down and select ASSIGN if not already assigned.
- From the Test Suite tab, select from the following linked tests then proceed to the specific instructions.
- Manual Order Indicator for Manual System for Pre-Registered / On-Demand Format
- Manual Order Indicator for Manual System (Mass Quotes) for Pre-Registered / On-Demand Format
- Manual Order Indicator for ATS System for Pre-Registered / On-Demand Format
- Manual Order Indicator for ATS System (Mass Quotes) for Pre-Registered / On-Demand Format
- Manual Order Indicator for Semi Automated System for Pre-Registered / On-Demand Format
- Manual Order Indicator for Semi Automated System (Mass Quotes) for Pre-Registered / On-Demand Format
- Use the Instrument(s) drop down menu to choose an instrument and channel and click SELECT.
- Click the START TEST button.
Note:
If a test is not proceeding to the next step, clicking the Refresh button (
) below the test steps may resolve the issue.
Referential information is included for messages sent / received during the test.
Manual Order Indicator for Manual System for Pre-Registered / On-Demand Format
The purpose of this test case is to verify how customer is using Manual Order Indicator tag.
- To run the Manual Order Indicator for Manual System test:
Note: This test is used for both Pre-Registered and On-Demand formats. The above image shows the Pre-Registered version of the test.
- Over an iLink connection, submit a Limit Day Order [35=D (tag 40-OrdType=2, tag 59-TimeInForce=0)] with the proper Manual Order Indicator tag 1 [tag 1028-ManualOrderIndicator=1(manual)].
- Receive and Process Execution Report - New Order (35=8, 39=0).
Manual Order Indicator for Manual System (Mass Quotes) for Pre-Registered / On-Demand Format
The purpose of this test case is to verify how customer is using Manual Order Indicator tag.
- To run the Manual Order Indicator for Manual System (Mass Quotes) test:
Note: This test is used for both Pre-Registered and On-Demand formats. The above image shows the Pre-Registered version of the test.
- Over an iLink connection, submit a two-sided Mass Quote (35=i) with the proper Manual Order Indicator tag 1 [tag 1028-ManualOrderIndicator=1(manual)].
- Receive and process Mass Quote Acknowledgment.
Manual Order Indicator for ATS System for Pre-Registered / On-Demand Format
The purpose of this test case is to verify how customer is using Manual Order Indicator tag.
- To run the Manual Order Indicator for ATS System test:
Note: This test is used for both Pre-Registered and On-Demand formats. The above image shows the Pre-Registered version of the test.
- Over an iLink connection, submit a Limit Day Order [35=D (tag 40-OrdType=2, tag 59-TimeInForce=0)] with the proper Manual Order Indicator tag 0 [tag 1028-ManualOrderIndicator=0(automated)].
- Receive and Process Execution Report - New Order (35=8, 39=0).
Manual Order Indicator for ATS System (Mass Quotes) for Pre-Registered / On-Demand Format
The purpose of this test case is to verify how customer is using Manual Order Indicator tag.
- To run the Manual Order Indicator for ATS System (Mass Quotes) test:
Note: This test is used for both Pre-Registered and On-Demand formats. The above image shows the Pre-Registered version of the test.
- Over an iLink connection, submit a two-sided Mass Quote (35=i) with the proper Manual Order Indicator tag 0 [tag 1028-ManualOrderIndicator=0(automated)].
- Receive and process Mass Quote Acknowledgment.
Manual Order Indicator for Semi Automated System for Pre-Registered / On-Demand Format
The purpose of this test case is to verify how customer is using Manual Order Indicator tag.
- To run the Manual Order Indicator for Semi Automated System test:
Note: This test is used for both Pre-Registered and On-Demand formats. The above image shows the Pre-Registered version of the test.
- Over an iLink connection, submit a Limit Day Order [35=D (tag 40-OrdType=2, tag 59-TimeInForce=0)] with Manual Order Indicator tag set to 1 [tag 1028-ManualOrderIndicator=1(manual)].
- Receive and Process Execution Report - New Order (35=8, 39=0).
- Submit a Limit Day Order [35=D (tag 40-OrdType=2, tag 59-TimeInForce=0)] with Manual Order Indicator tag set to 0 (tag 1028-ManualOrderIndicator=0).
- Receive and process Execution Report - New Order (35=8, 39=0).
Manual Order Indicator for Semi Automated System (Mass Quotes) for Pre-Registered / On-Demand Format
The purpose of this test case is to verify how customer is using Manual Order Indicator tag.
- To run the Manual Order Indicator for Semi Automated System (Mass Quotes) test:
Note: This test is used for both Pre-Registered and On-Demand formats. The above image shows the Pre-Registered version of the test.
- Over an iLink connection, submit a two-sided Mass Quote (35=i) with the proper Manual Order Indicator tag 1 [tag 1028-ManualOrderIndicator=1(manual)].
- Receive and process Mass Quote Acknowledgment.
- Over an iLink connection, submit a two-sided Mass Quote (35=i) with the proper Manual Order Indicator tag 0 (tag 1028-ManualOrderIndicator=0).
- Receive and process Mass Quote Acknowledgment.