Globex Advisory Notice

 | 
To All iLink� Users
From John M. Restivo, Director GLOBEX� Control Center
Subject System Update #10 Cancellations of working orders
Effective Date 04/09/02
Notice Number SU#0210
CAUSE:

At approximately 10:30 AM CT while working on a production issue, all iLink working orders were inadvertently cancelled via Firmsoft. All customers received cancel acknowledgements on these orders.

RESPONSE:

Senior and development staff immediately generated a list of affected orders. The GCC placed calls to customers and apprised them of the situation. A detailed list of all cancelled orders by firm was created and sent to the firms so they could complete their reconciliation of the affected orders.

RESOLUTION:

Effective immediately, production access to Firmsoft has been eliminated for all development staff.

If you have any questions, please call the GCC at 312-456-2391 option 2.