In cases where the iLink session undergoing additional processing exceeds the number of messages permitted, the session will be logged out and all in-flight messages rejected. The number of messages permitted is consistent for all iLink sessions and configured by the exchange (currently 15 messages for Future & Options and 50 messages for BrokerTec Markets). CME Group reserves the right to change the session logout threshold at any time without notice.

...

  • the MSGW generates four Logout messages—one Logout for each message, but sends only the first. When the client system logs in, the Logon Acknowledgment tag 34-MsgSeqNum=204 rather than 201.
    • As a result, the client system may receive a Logon Confirmation (tag 35-MsgType=A) message with a sequence number higher than expected after the next client system login.

      Info

      The client system cannot submit a iLink 2 Resend Request message to recover unsent logout messages.

    • These logout messages will not be counted towards Auto Port Closure.

...

When an MSGW session is undergoing additional safeguard processing and is logged out due to the number of in-flight messages, CME Globex will send a Logout message including the following tag 58=<Reject Reason> and reject all in-flight messages.

Message Type

Logout Reason

Tag 58-Text

Logout (tag 35-MsgType=5)

  • Exceeding the session logout threshold

MSGW safeguard exceeded: no. of messages

  • Hard TCP Disconnect (i.e. without sending a logout)
  • Customer initiated logout
  • Customer sends an invalid message (e.g. a lower than expected message sequence number)

Messages rejected due to session disconnect